MP198 Air-Quality Gas Sensor
Principle Introduction:
MP198 gas sensor is for air quality,It adopts multilayer thick film manufacturing technolgy. The heater and metal oxide semiconductor material on the ceramic substrate of subminiature Al2O3 are fetched out by electrode down-lead, encapsulated in metalsocket and cap. Conductivity of the sensor is affected by theconcentration of target gas. The higher the concentration is, the higher conductivity of sensor gets. Users can adopt simple circuit to convert to convert variation of conductivity into output signal corresponding to gas concentration.
Applications :
It is used in occasions such as household and office for harmful gas detection,automatic exhaust device,air cleaner & etc.
Technical parameters :
Model | MP198 | ||
Sensor Type | Semiconductor flat surfaced sensor | ||
Standard Encapsulation | Metal Cap | ||
Detection Gas | benzene,toluene,methanal,alcohol,smoke | ||
Detection range | 0.5~1000ppm(alcohol) | ||
Standard circuit | Loop voltage | VC / VH | VC:≤24V DC VH:5.0V±0.1V AC or DC |
Load resistance | RL | Adjustable | |
sensor features in standard test condition | Heating resistance | RH | 95Ω±10Ω(Room Tem.) |
Heating consumption | PH | ≤300mW | |
Surface resistance | RS | 1KΩ~15KΩ(in 10ppm alcohol) | |
Sensitivity | S | Rs(in air)/Rs(in 10ppm alcohol)≥2 | |
Concentration slope | α | ≤0.6(R 50ppm/R 10ppm alcohol) | |
Standard condition of test | Temperature, humidity | 20℃±2℃;65%±5%RH | |
Standard test circuit | VC/VH :5.0V±0.1V | ||
Warm-up time | More than 48 hours |